Today, we'll be talking about
how to separate enantiomers
-
from each other.
-
Enantiomers are like your
left and right hands.
-
They are mirror
images of each other,
-
but they look almost identical.
-
Remember that much like we
use right and left to describe
-
which hand is which, scientists
use the letters S and R
-
to designate which
enantiomer is which,
-
when you only have
one chiral center.
-
However, when you have
multiple chiral centers,
-
there are other ways of
designating enantiomers.
-
But we won't be getting
into that today,
-
because that's much
more complicated.
-
Here we have a set
of enantiomers.
-
This is the S confirmation
of thalidomide,
-
and here on the right
is the R confirmation.
-
Why does it matter that we have
two different confirmations?
-
Well, you can see the
difference quite clearly
-
at the chiral center,
where one of the groups
-
points into the screen and the
other points out of the screen.
-
And just because of the
simple change in confirmation,
-
that S version was found to
lead to terrible birth defects
-
when consumed by mothers.
-
And because of
this, drug companies
-
now try to make sure that the
active ingredient in their drug
-
is only one
particular enantiomer.
-
So how would we go about
separating these two?
-
One technique that you
could use is chiral column
-
chromatography.
-
You would need a stationary
phase that is chiral,
-
meaning something that
will only bind either
-
to the R confirmation or the
S confirmation of your desired
-
enantiomer.
-
So how does the chiral
stationary phase only
-
bind to one of the enantiomers?
-
Picture the two enantiomers
as your right and left hand.
-
If your right hand tries
to shake another person's
-
right hand it seems normal,
the two fit together properly.
-
But if your right hand tries
to shake your own left hand,
-
it doesn't seem like
they line up quite right.
-
That's the exact same
thing that happens
-
with the chiral stationary
phase and the wrong enantiomer.
-
Next, what you do is you'd load
that mixture of enantiomers.
-
So on top here, you
might see that you
-
have some kind of
band of your mixture.
-
This is racemic,
meaning that it has
-
a 50/50 mixture of enantiomers.
-
So that's what you're
seeing here in the yellow.
-
If we take a closer
look, you'll see
-
that this has some
of the S confirmation
-
and some of the R
confirmation too thrown in.
-
-
And as this moves through
the stationary phase,
-
so once you open up the
stop cock, what you'll see
-
is that if the R
enantiomer was the one that
-
binds tightly to the
stationary phase,
-
it won't move very quickly.
-
But with the S enantiomer,
it might be racing through
-
since it's not
really interacting
-
that much with the
stationary phase,
-
and prefers to interact
with the mobile phase.
-
Once you've collected all of
the S enantiomers in your flask,
-
all you'll have
left in the column
-
is the R enantiomer, which
is pretty tightly bound
-
to the chiral stationary phase.
-
Next, what you'd do is
when you have this column,
-
you'd want to pour
in lots of solvent
-
so that you can get the
R enantiomer to come out.
-
Because as this pushes
down through the column,
-
it will take the R
enantiomer with it,
-
giving you just the R
enantiomer in your flask.
-
And there you've done a
successful chiral resolution.
-
The same principle can also be
applied to gas chromatography.
-
Let's quickly review how
gas chromatography works.
-
You insert your sample in
here, a gas flows through,
-
and then it goes into
this long to that
-
contains the stationary
phase and mobile phase,
-
and goes to the detector.
-
And if we were to
zoom in on this--
-
and draw this just
kind of a long tube--
-
again what you'd see is that if
this time the stationary phase
-
was attracted to the
S enantiomer instead,
-
you'd see that the S enantiomer
is sticking to the sides,
-
sticking to the
stationary phase,
-
while the R enantiomer races
through with the mobile phase.
-
So there are actually
a number of other ways
-
you can separate
enantiomers, but those
-
tend to be much
more complicated.
-
These are just two of the
common ways you can do it.
-
And in both of
them, whether you're
-
doing column chromatography with
a solid stationary phase or gas
-
chromatography was a
liquid stationary phase,
-
the important thing to remember
is that your stationary phase
-
should be chiral and bind to
the enantiomer that you want.
-