WEBVTT 00:00:00.000 --> 00:00:03.780 This demonstration is how to prepare a wet mount. 00:00:03.780 --> 00:00:05.810 The purpose of doing a wet mount is 00:00:05.810 --> 00:00:08.060 to check for the motility of a cell 00:00:08.060 --> 00:00:11.220 and also the size of a cell. 00:00:11.220 --> 00:00:15.170 Make sure your gloves and your goggles are on. 00:00:15.170 --> 00:00:17.420 I'll be demonstrating how to do a wet mount when 00:00:17.420 --> 00:00:19.520 the starting material is a liquid 00:00:19.520 --> 00:00:21.860 and then when the starting material is coming 00:00:21.860 --> 00:00:24.620 from a colony on a Petri plate. 00:00:24.620 --> 00:00:28.340 Start by taking a slide from the box. 00:00:28.340 --> 00:00:30.480 You will need a cover slip. 00:00:30.480 --> 00:00:34.230 Cover slips are squares of either glass or plastic, 00:00:34.230 --> 00:00:37.580 and they are separated by pieces of tissue paper. 00:00:37.580 --> 00:00:40.260 When the starting material is a liquid, 00:00:40.260 --> 00:00:42.060 take a drop of the material. 00:00:42.060 --> 00:00:45.570 Put it in the center of the slide. 00:00:45.570 --> 00:00:48.870 Take your cover slip. 00:00:48.870 --> 00:00:52.410 Hold it at a 45-degree angle, touching the slide, 00:00:52.410 --> 00:00:55.290 and gently drop it. 00:00:55.290 --> 00:00:59.220 When the starting material is a colony on a Petri plate, 00:00:59.220 --> 00:01:03.240 you will take a slide, and you're 00:01:03.240 --> 00:01:06.030 going to put a drop of deionized water 00:01:06.030 --> 00:01:08.210 in the center of the slide. 00:01:08.210 --> 00:01:11.470 00:01:11.470 --> 00:01:14.020 Then using aseptic technique, you'll 00:01:14.020 --> 00:01:16.370 be using your inoculating loop. 00:01:16.370 --> 00:01:18.880 You'll need to sterilize your inoculating 00:01:18.880 --> 00:01:22.500 loop by putting the loop into the flame of the Bunsen burner. 00:01:22.500 --> 00:01:27.490 00:01:27.490 --> 00:01:30.010 Remove the lid from the plate. 00:01:30.010 --> 00:01:31.960 If there's an area on the plate where 00:01:31.960 --> 00:01:35.240 you can touch the loop to cool it beforehand, 00:01:35.240 --> 00:01:37.390 that would be a good idea. 00:01:37.390 --> 00:01:40.630 Touch the surface of a colony. 00:01:40.630 --> 00:01:43.810 Immediately put the lid back on the plate. 00:01:43.810 --> 00:01:47.590 Put the loop in the drop of water. 00:01:47.590 --> 00:01:51.610 Spread it around about the size of a dime. 00:01:51.610 --> 00:01:57.040 Sterilize the loop before you put it on the bench, 00:01:57.040 --> 00:02:00.920 and turn off the Bunsen burner. 00:02:00.920 --> 00:02:03.020 Take a cover slip. 00:02:03.020 --> 00:02:08.830 Hold it at a 45-degree angle and gently drop it on the sample. 00:02:08.830 --> 00:02:12.000